• The Hospital Equipment Anesthesia Machine with Patient Monitor for Optional Jinling-850
  • The Hospital Equipment Anesthesia Machine with Patient Monitor for Optional Jinling-850
  • The Hospital Equipment Anesthesia Machine with Patient Monitor for Optional Jinling-850
  • The Hospital Equipment Anesthesia Machine with Patient Monitor for Optional Jinling-850

The Hospital Equipment Anesthesia Machine with Patient Monitor for Optional Jinling-850

Type: Anaesthesia Machine
Kind: Sugical Room
Certification: CE, ISO13485
Group: Adult
LCD Display: With LCD Display
Flowmeters: 5-Tube Flowmeters, O2 & N2o & Air;0.1 L/Min ~ 10 L
Samples:
US$ 5200/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2009

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
Jinling-850
Oxygen Flush
25~75 L/Min
Air Pressure
O2:0.3~0.5MPa,N2o:0.3~0.5MPa,Air:0.3~0.5MPa
Respiration Mode
A/C, Ippv, Sippv, Imv, Simv, Pcv, Vcv, Peep, Sigh,
Tidal Volume
0~1500 Ml;
Respiration Frequency
1~99bpm
I:E
4:1~1:10
Colour
White
O2 Concentration
21%~100%
Peep
1.5~10 Hpa;
Transport Package
Stand Expert Packing
Specification
Iso, CE
Trademark
Seeuco
Origin
Nanjing, Jiangsu, China
HS Code
90189070
Production Capacity
100units

Product Description

The anesthesia machine price 
 
TECHNIQUES SPECIFICATIONS
Physical specifications 
Screen:  10.4 ''  LCD  Display Screen
Suitable Adult & Child
 Mode: pneumatically powered and electrically controlled system
Working Mode: Closed; Semi-Closed; Semi-Open
Circuit Breathing circuit integrated standards
Flowmeters: 5 Tubes Flowmeters:  O2:0.1~10L/Min,  N2O:0.1~10L/Min; Air: 0.1~10L / Min
Trolley:  Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Drawer unit TWO drawers  totally extractable
Technical Specifications:
Gas requirement:  Medical oxygen and nitrous oxide with a pressure ranging from O2: 0.32~0.6MPa ;   NO2: 0.32 MPa to 0.6 MPa.
safety valve  <12.5  kPa
Respiratory Rate 1~99bpm
oxygen concentration in the mixed gas N2O/O2  > 21%
Oxygen Flush:  25~75 L/min
modes of ventilation A/C, IPPV, SIPPV, IMV, SIMV, PCV, VCV, PEEP, SIGH, PEEP, MANUAL
PEEP: 0 ~ 20 hPa
Ptr:  -10 ~ 20 hPa
IMV frequency: 1 ~ 20 bpm
I/E Ratio: 8:1 ~ 1:10, Has the inverse ratio ventilation
Tidal Volume 0 ~ 1500 ML
Inspiratory Plateau: 0~1s
O2 Concentration: 21%~100%
Sigh:  one deep breath per 70 ~ 120 controlled respirations, the inspiration time is 1.5 times of the setting point
Maximum safety pressure: ≤ 12.5 kPa
Pressure limit range: 0 ~ 6.0  kPa
Airway pressure alarm: Audible and visual and with yellow and red color indicating Lower: 0.2kPa~5.0kPa;   Upper: 0.3~6.0  kPa
±0.2 kPa
Tidal volume alarm: Audible and visual and with yellow and red color indicating upper alarm: 50 to 2000ml, lower alarm: 0~1800ml
Oxygen concentration alarm: Audible and visual and with yellow and red color indicating upper alarm: 21% ~100%;  lower alarm:10%~80%
Power Supply Alarm Ac/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.
Operating conditions
Ambient temperature:  10 ~ 40oC
Relative humidity: no higher than 80 %
Atmospheric pressure: 860 hPa ~ 1060 hPa
Power requirement:  100-120 Vac, 50/60 Hz;  
Attention: the AC power supply used for the anesthesia machine must be well   grounded.
Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. 
Storage
Ambient temperature:  -15oC ~ +50oC
Relative humidity:  no higher than 95 %
Atmospheric pressure:  86 kPa ~ 106 kPa.
  It should be stored in a room without corrosive gas and well ventilated
Package
packaging box comply with the requirement of GB/T 15464
  Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
  Moisture protection and rain protection to ensure that product is protected from natural damage. 
Safty & Alarm
Oxygen Alarm It alarms when the oxygen  supply from pipe or cylinders lower than 0.2MPa
Ventilation Volume Alarm Lower: 0~12L/Min;   Up: 18L/ Min
Power Alarm It Alrmas while AC and DC supply failure ; Keep alraming  time: >120s
Air Tract Pressure Alarm Lower: 0.2kPa ~5.0 kPa;  Up: 0.3kPa ~ 6.0kPa
STANDARD CONFIGURATIONS  
QTY NAME
1 set Main unit
1 set Built in ventilator
1 set 5-tube flow meter
2  set vaporizer
1 set Patient circuit
1 set bellow
1 set Na lime tank
1 set Diaphragm electronic sensor
1 pic Oxygen pressure reducer
2 pics A leather bag ( Blue)
5 pics Threaded pipe
2 pics mask
1 set Oxygen probe
1 set Tools with the machine
1 set User Manual (English Version)
Optional Patient Monitor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now