• ICU Equipment Ce Approved Respiratory Machine Medical Ventilator
  • ICU Equipment Ce Approved Respiratory Machine Medical Ventilator
  • ICU Equipment Ce Approved Respiratory Machine Medical Ventilator
  • ICU Equipment Ce Approved Respiratory Machine Medical Ventilator
  • ICU Equipment Ce Approved Respiratory Machine Medical Ventilator

ICU Equipment Ce Approved Respiratory Machine Medical Ventilator

Type: Ventilator
Breathing Mode: Ippv, Sippv, Imv, Simv, Peep, Manu, Sigh and So on
Tidal Volume: 50~1200ml
Oxygen Concentration: < 45%
Ventilation Capacity Per Minute: No Less Than 18L
I:E: 1:1.5;1:2.0;1:2.5;1:3.0
Samples:
US$ 1200/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

Contact Supplier

Diamond Member Since 2009

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
PA-500
Certification
CE, ISO13485
Group
Adult
LCD Display
Without LCD Display
Transport Package
Export Standard Package
Specification
CE
Trademark
Seeuco
Origin
Nanjing, Jiangsu
Production Capacity
50units/Week

Product Description

ICU Equipment CE Approved Medical Ventilator  PA-500

Breathing Mode: IPPV, SIPPV, IMV, SIMV, PEEP, Manu, Sigh and so on;
Tidal Volume Adjustment 50~1200ml
Ventilation Capacity per Minute ≥ 18L
Oxygen Concentration < 45%
Ventilator Conformance ≤ 30mL/kpa
Respiratory Rate 6~60/m
I/E Ratio: 1: 1.5, 1: 2.0, 1: 2.5, 1: 3.0;
Maximum Safe Pressure ≤ 6.0kPa
(Ptr) Range -0.4~1.0kPa
Transfer Time from Controlled to Assistant Respiration 6s
Air Flow Adjustment 1~12times /m
PEEP 0.1~1.0kPa
Sigh Volume: 150% of tidal volume
Oxygen Consumption: ≤ 1.5mPa change in pressure after 1-hour operation of oxygen cylinder of 12250kPa/40
ICU Equipment Ce Approved Respiratory Machine Medical Ventilator


 
Breathing Mode IPPV, SIPPV, IMV, SIMV, PEEP, Manu, Sigh and so on;
Tidal Volume Adjustment 50~1200ml
Ventilation Capacity per Minute ≥18L
Oxygen Concentration <45%
Ventilator Conformance ≤30mL/kpa
Respiratory Rate 6~60/m
I/E Ratio: 1:1.5, 1:2.0, 1:2.5, 1:3.0;
Maximum Safe Pressure ≤6.0kPa
(Ptr) Range -0.4~1.0kPa
Transfer Time from Controlled to Assistant Respiration 6s
Air Flow Adjustment 1~12times /m
PEEP 0.1~1.0kPa
Sigh Volume: 150% of tidal volume
Oxygen Consumption:≤1.5mPa change in pressure after 1-hour operation of oxygen cylinder of 12250kPa/40L.

Send your message to this supplier

*From:
*To:
avatar Ms. Helena
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Product Groups

Contact Supplier

Diamond Member Since 2009

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company
Plant Area
101~500 square meters
Management System Certification
ISO 9001, ISO 13485