Customization: | Available |
---|---|
Application: | Orthopedic, Abdominal, Ent, Neurosurgery, Microsurgery, Anorectal, Urology, Burns |
Material: | Metal, Plastic |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Anesthesia ventilator
Pneumatically driven electronically controlled system
Built-in ventilator, 10.4" LCD display
With 1 patient circuit for adult (Optional:patient circuit for children)
5-tube flowmeters, O2 & N2O & Air;0.1L/Min ~ 10 L/Min;
Two vaporizers,Enflurane/Isoflurane/Sevoflurane; (Optional: Halothane)
Oxygen Flush: 25~75 L/Min;
Respiration Mode: IPPV, SIPPV(VCV), IMV,SIMV, PEEP, Manu, Sigh
Tidal Volume: 0~1500 mL;I:E: 8:1~1:10
Respiration Frequency: 1~99bpm;
PEEP: 1~10 hPa;
Ptr: -10~10 hPa;
CO2 absorber capacity: 1 kg
Lung compliance: ≤ 30mL/kPa;
IMV frequency: 1~12bpm
Inspiratory Plateau: 0~1S;
O2 Concentration: 21%~100%
Alarm parameter: upper /lower limit ofairway pressure, tidal volume exceed limitation, no tidal volume output, apnea,AC power malfunction, battery low power
Patient Monitor
12.1''TFT large screen of high resolution
ECG: 5-lead, gain:×2.5mm/mV ×5.0mm/mV×10mm/mV ×20mm/mV, analysis of ST segment and abnormal of heart rate(anti-defibrillate, anti-HF electrotome)
Heart Rate: 20~250bpm
RESP: Impedance, range: 0~100bpm
SpO2: 0%~100%
Pulse Rate: 20~250bpm
NIBP: SBP, DBP, MBP, 10~270mmHg interval ofautomatic measurement 1~90min adjustable
TEMP: 0~50ºC
Alarm: Audio and visual alarm
Tendency record 96 hours
Loop part
Integrated design, integrated breathingcircuit
Evaporator
High-precision double evaporators configuration, enflurane or isoflurane or Sevflurane or Haloflurane
Concentration adjustment range: 0.5 ~ 5%VOL
Evaporator flow, pressure, and automatictemperature compensation function
Self-locking feature
Configuration
Vaporizer: Two vaporizers, Enflurane/Isoflurane/Sevoflurane(Option: Halothane)
Anesthesia gas concentration range: 0.5~5%
Soda lime absorption system: resistance tohigh temperature of 176 degrees Celsius.
CE & ISO certificates approved
Model |
850 (Standard Model) |
850 (Advanced Model) |
Display |
8.4 inch TFT display |
10.4 inch TFT display |
Flowmeter Range |
O2: 0.1-10L/min |
|
N2O: 0.1-10L/min |
||
Air: 0.1-10L/min |
||
Ventilation Mode |
IPPV, SIPPV, VCV, IMV, SIMV, MANUAL, Standby |
IPPV, SIPPV, VCV, PCV, IMV, SIMV, MANUAL, Standby |
Back-up Power Supply |
At least 4 hours |
|
Tidal Volume |
Adjustable range: 10-1500ml |
|
Display range: 0-2000ml |
||
Respiratory Rate |
1-100bpm |
|
Inspiratory/Expiratory (I:E) Ratio |
8:1-1:10 (capable of inverse ratio ventilation) |
|
PEEP Range |
0-20cmH2O (electronically controlled) |
|
Inspiratory Pressure Trigger Range |
.-10-10cmH2O (electronically controlled) |
|
SIGH |
1 sigh breath in every 80-120 breaths |
|
Inhaled Oxygen Concentration Monitor |
21-100% |
|
SIMV Rate |
1-20bpm |
|
Inspiratory Plateau |
0-1 second |
|
Vaporizer Concentration Ranges |
0-5% |
|
Vaporizer Slots |
Double PA-I type slots |