Medical 500mA Full Wave Radiography X-ray Unit
Feature:
1, Automatic and manual control programs:
Porgrammable functions, provides 90 memory programs for radiography. The parameters can also be set manually.
2, X-ray tube protection:
X-ray tube heat capacity and load capacity are managed and protected by computer programs, to allow maximum utilization of the tube capacity and radiographic parameters.
3, Anatomical exposure selection:
Exposure parameters can be set based on patient body size and exposure positions. The parameters can also be corrected and stored manually.
4, Safety function:
The error self-diagnosis function can determine problems quickly and accurately. It can execute protection automatically and display error code.
Color |
White |
X-ray Tube Part Number |
Xd52-30.50/125-T2a |
X-ray Tube Power |
30/50kw |
X-ray Tube Lowest Ars(50Hz) |
2800rpm |
X-ray Tube Target Angle |
17.5° |
ComponentSpecifications
High Frequency
GeneratorSystem Console: FS302-1A HV Transformer Assembly: FSB302-1A
Maximum Output Power: 33.3kW (Intermittent mode)
Radiography Tube Voltage: 44~125kV step 2kV
Radiography Tube Current: 32mA~500mA by steps
Exposure Time: 0.02S~5S by steps
90 Radiography Combinations
Power: 380VAC 3-Phase Frequency: 50Hz Allowed Internal Resistance: 380V: 0.75Ω Fault Detection and Diagnosis
X-ray Tube AssemblyPart Number: XD52-30.50/125-T2A
Rated Focal Spot Value: 1.0mm/2.0mm
Power: 30/50kW
Heat Storage of Tube Assembly: 190kHU
Lowest ARS(50Hz): 2800rpm
Target Angle: 17.5°
Radiography TablePart Number: SC4-1
External Dimension(Length* Width*Height): 2000mm*730mm*690mm
Tabletop Movement(Longitudinal): 1200mm
Tabletop movement(Lateral): 200mm
X-ray tube assembly Movement(Longitudinal): 580mm
Rotation Range of X-ray Tube Around Lateral Arm: +90° ~-90° , motorized control
Strut Rotation Range: +180° ~-180° , and the interval of 90° Could be located. (This function is need to rotation type strut. )
Vertical dimension of X-ray tube focal and ground: ≥ 1030mm~1740mm The range of X-ray tube focal and film: 1100mm
Tabletop Locking Mode: Electromagnetic lock, braking force≥ 100N
Tabletop Locking Control: Footswitch (normally closed)
Bucky Vibration Mode: Fixed
Gird Size: 388mmx464mm
Bucky specification: F0: 100cm, r: 10, N: 40L/cm
Film Loaded in Bucky: Max 14× 17
Distance between Tabletop and Bucky Film ≤ 80mm
Longitudinal Travel of Bucky(SID): 580mm
Bucky locking: Electromagnetic, braking force≥ 100N
CollimatorPart Number: XS1-2
External Dimension: 250mm× 224mm× 250mm
Radiation Field(SID=65cm) Max: 35cm× 35cm; Min: 0cm× 0cm
Operation Mode: Manual
Optional Components (Optional)
ComponentSpecifications
Vertical Bucky
StandPart Number: LS-3
Vertical Movement: ≥ 1000mm
Maximum Dimension: 8*10-14*17
Grid (replaceable)
N: 40L/cm; R8\r10\r12; F0: 150cm\180cm\200cm