Perlong Medical Neonatology Equipment Infant Incubator Bi-3000

Product Details
Customization: Available
Type: Neonatology
Function: Infant Incubator
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2009

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
101~500 square meters
Management System Certification
ISO 9001, ISO 13485
  • Perlong Medical Neonatology Equipment Infant Incubator Bi-3000
  • Perlong Medical Neonatology Equipment Infant Incubator Bi-3000
  • Perlong Medical Neonatology Equipment Infant Incubator Bi-3000
  • Perlong Medical Neonatology Equipment Infant Incubator Bi-3000
  • Perlong Medical Neonatology Equipment Infant Incubator Bi-3000
  • Perlong Medical Neonatology Equipment Infant Incubator Bi-3000
Find Similar Products

Basic Info.

Model NO.
BI-3000
Theory
Constant Temperature
Certification
CE, ISO13485
LCD Display
Without LCD Display
Group
Neonate
Mode
Air,Infant
Color
White
Warranty
1 Year
Certificate
Ce ISO
Mattress
450mm
Connector
RS-232
Alarm
Power Failure,Fan Failure,Sensor Failure
Front Access Panel
826*310mm
Mattress Tray Size
630*360mm
Air Temperature Adjustment
20-37′c,37-39′c
Transport Package
Wooden Case
Specification
1000*580*800,55kg 1000*580*800,65kg 1180*580*60,9k
Trademark
perlong medcial
Origin
Jiangsu
Production Capacity
120/Week

Product Description

Infant Incubator
 
BI-3000
 
Specifications
Model BI-3000
Canopy Specifications
Mattress (canopy) 450mm
Access Port 6 (2 Iris ports)
Self-sealing Tube Ports 4
Front Access Panel 826x310mm
Mattress Tray Size 630x360mm
Technical Specifications
Temperature Mode (Servo Controlled) air, infant
Air Temperature Adjustment Range 20°C~37°C, 37~39°C
Infant Temperature Adjustment Range 30°C~37°C, 37~38°C
Infant Sensor Accuracy ≤0.3°C
Relative Humidity Display Range 5%~99%
Temperature Fluctuation ≤0.5°C
Uniformity of Mattress Temperature ≤0.8°C
Time to Warm Up ≤30 min
Noise Level within Canopy ≤55dB
Alarms
Power Failure Alarm Yes
Fan Failure Alarm Yes
Sensor Failure Alarm Yes
Air Temperature Deviation Alarm ±3.0°C
Infant Temperature Deviation Alarm ±1.0°C
Air Temperature Exceeds set Limit Alarm ≤38.0°C; ≤40.0°C
Infant Temperature Exceeds set Limit alarm ≤38.0°C; ≤39.0°C
System Failure Alarm Yes
Mute Alarm Function Yes
Operational Environment
Temperature within Operational Environment +20°C~+30°C
Relative Humidity within Operational Environment 5%~99%
Velocity of Air Flow within Operational Environment <0.3m/s
Other Specifications
RS-232 connector Yes
Tilt of Infant Bed (Adjustment Range) ±10° step-less
Maximum Load of Mattress Tray 5kg
Maximum Load of IV Stand 2kg
Maximum Load of Cabinet 6kg
Perlong Medical Neonatology Equipment Infant Incubator Bi-3000Perlong Medical Neonatology Equipment Infant Incubator Bi-3000

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More