Horizontal Cylindrical Sterilisateur Esterilizacion Machine Autoclave Pressure Steam Sterilizer

Theory: Pressure Steam
Type: Pressure Steam Sterilization Equipments
Certification: CE, ISO13485
Electric Tension: 380V
LCD Display: With LCD Display
Working Pressure: 0.22mpa
Customization:
Diamond Member Since 2009

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
PTS-280YDA
Time of Sterilization
0-60 Min
Adjustment of Temperature
40c- 134c
Time of Drying
0-60 Min
Working Temperature
134c
Transport Package
Export Packing
Specification
ISO
Trademark
Seeuco
Origin
Jiangsu, China
Production Capacity
50units/Week

Product Description

Horizontal Cylindrical Autoclave Pressure Steam Sterilizer

Features:
1. The steam can't go through to chamber when the door don't close, and the pilot off inform. You can process dry operation.
2. When the pressure inner over 0.027Mpa. The door be locked and can't be opened
3. If you not choose the sterilizer time and start the machine, buzzer sound will be alarm
4. Opening the door by mistake in the course of start, the jacker valve and chamber valve will auto shut-off
5. Lacking water the pilot light on, heating and sterilize pilot light off, the buzzer sound and auto release steam
6. Overload and leakage protection, when leakage or over current occur, it auto off the power
7. Temperature controlled not work and the inner pressure over 0.165mpa, the safety valve auto start open
Item No. PTS-280YDA PTS-200YDA PTS-150YDA
Sterilizing  chamber volume 280L(φ600×1000mm) 200L(φ515×1000mm) 150L(φ440×1000mm)
working pressure 0.22 MPa
working temperature 134C
Adjustment of temperature 40C- 134C
Time of sterilization 0-60 min
Time of drying 0-60 min
Heat average ≤± 2C
Power supply 12KW/380V 50Hz 9KW/380V 50Hz 9KW/380V 50Hz
N/G.W 340/440 KG 290/380 KG 270/360 KG


Horizontal Cylindrical Sterilisateur Esterilizacion Machine Autoclave Pressure Steam SterilizerHorizontal Cylindrical Sterilisateur Esterilizacion Machine Autoclave Pressure Steam SterilizerHorizontal Cylindrical Sterilisateur Esterilizacion Machine Autoclave Pressure Steam SterilizerHorizontal Cylindrical Sterilisateur Esterilizacion Machine Autoclave Pressure Steam SterilizerHorizontal Cylindrical Sterilisateur Esterilizacion Machine Autoclave Pressure Steam Sterilizer
 