GeneratorRadiography kV Range 44 to 125kV total 41 steps
Radiography mA Range 30 to 500mA total 8 steps
Exposure Time 0.02 to 5s total 23 steps
Fluoroscopy kV Range 44 to 110kV
Fluoroscopy mA Range 0.5 to 5mA continuous regulation
TOMO Tomographic capability
Anatomical Programing Yes
Power Supply 380VAC± 38VAC, 3-phase
Power Frequency50/60Hz± 1Hz
Power Capacity
50kVA
X-ray TubeXD52-30.50/125 XD51-20.40/125
Rated Voltage125kV 125kV
Rated Focal Spot Value1.0/2.0mm 1.0/2.0mm
Max Power(0. Ls)(kW) 30 (small) / 50 (big) 20 (small) / 40 (big)
Rotate Speed (min1/rpm)2800 (50Hz) 2800 (50Hz)
Anode Heat Storage Capacity190, 000HU 140, 000HU
Heat Storage of Tube Assembly1, 250, 000HU 1, 250, 000HU
Diagnostic TableFilm Size and Exposure Procedure8" × 10"
10" × 12"
11" × 14"
14" × 14"
Send Film Method Film feed driven by motor; Automatic skipping
Range of Movement ≥ 720mm ( longitudinally )
≥ 200mm ( transversely )
≥ 260mm for pressure direction, Press power: 80~100N
Pattern of Movement Driven electrically
Filtering Grid Fixed type; Grid ratio: R=8; Grid density: N=40L/cm
Focal distance: 70cm; Size: 14" × 14"
Range of Movement +90° ~ 0° ~ -15°
Pattern of Movement Driven electrically, at a speed of about 90° /30s
Range of Movement Able to be extended 30cm at the front end
Pattern of Movement Driven electrically, at a speed of about 3cm/s
Radiographic TableTabletop Length 2000mm
Tabletop Width 740mm
Tabletop Height 658mm
Tabletop Movement Longitudinal: 1200mm; Lateral: 200mm
Strut Movement Along Table (Longitudinal) 1200mm
DIS Travel while X-ray Tube Assembly Vertically Moving up and down 1100mm
Rotation Range of X-ray Tube Around Lateral Arm +120° ~ -120°
Strut Rotation Range +180° ~ -180°
Tabletop Locking electromagnetically locking, brake pressure≥ 100N
Tabletop Locking Control footswitch (normally closed)
Bucky Vibration Mode Fixed type
Focus fo=100
Grid Size 14" X 17" ( 356mm × 432mm )
Film Loaded in Bucky Max 14" × 17"
Longitudinal Travel of Bucky 500mm
Bucky Locking electromagnetically locking, brake pressure≥ 100N
Image SystemWorking Mode Continuous
Scanning Ratio 2.1 Interlaced
Number of Scanning Line 625TCL
Number of Frame per Second 25
Aspect Ratio 4: 3
CCD Camera 400, 000 pixels CCD
Resolution Horizontal Center≥ 800 TVL; Vertical Center≥ 400 TVL
Image IntensifierModel Thales
Input size9 inch (9"/6"/4.5")
Resolution46 lp/cm
DQE65%
Image Processing Function
Last image hold
8 images storage
Dynamic function
Static function
Digital mask circle
Automatic KV control
14 inch monitor 1set
Collimator
XS1-2 XS1-2
Mode of Adjustment Manuel Electrically-Driven
Maximum Tube Voltage150kV 150kV
Radiation Field [Max SID = 65cm] 350mm X 350mm 350mm X 350mm
Radiation Field [Min SID = 100cm]0 ≤ 50mm X 50mm
Time Limit of the Light Source≤ 60s N/A
Inherent Filtration 1.5 (mmAl) N/A
External Dimension (L× W× H)250× 224× 250mm 212× 212× 223mm
Moq |
one set |
Lead Time |
7days |