Patient Monitor, ECG Monitor, Perlong Medical manufacturer / supplier in China, offering Multi-Parameter 12.1 Inch TFT Display Patient Monitor Pdj-3000b, Defibrillator Monitor Medical Equipment PT-9000b, Ob-Cbii Operating Table Electrical Obstetric Delivery Bed and so on.

(/ )

Supplier Homepage Product ICU Equipment Patient Monitor Multi-Parameter 12.1 Inch TFT Display Patient Monitor Pdj-3000b

Multi-Parameter 12.1 Inch TFT Display Patient Monitor Pdj-3000b

Purchase Qty.:
(Pieces)
1-4 5+
FOB Unit Price: US $620 US $580
Purchase Qty. (Pieces) FOB Unit Price
1-4 US $620
5+ US $580
Get Latest Price
Production Capacity: 1000 PCS/Month
Transport Package: Export Standard Package
Payment Terms: L/C, T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: PDJ-3000B
  • Pediatric/Neonatal: 15-300bpm
  • Accuracy: ± 1 Bpm or ±1%
  • 72-Hours: Graphic and Tabular Trends of All Paramet
  • 32 Seconds: Full-Disclosure Waveform Revi
  • Specification: ISO, CE
  • HS Code: 98900000
  • Heart Rate Range: Adult: 15-300bpm
  • Lead Mode: 3-Lead or 5-Lead
  • Optional: 2-IBP, Etco2, and Thermal Prin
  • 72 Alarm Events of: All Parameters Recall
  • Trademark: Perlong
  • Origin: Nanjing, Jiangsu
Product Description

Specifications
1.ECG waveform:2 channels 
2.Heart rate range: Adult: 15-300bpm; Pediatric/Neonatal: 15-300bpm

ECG
Lead mode: 3-lead or 5-lead                  
Lead selection: I; II; III; avR; avL; avF; V
Heart rate range: Adult: 15-300bpm; Pediatric/Neonatal: 15-300bpm
ECG waveform: 2 channels                  
Accuracy: ± 1 bpm or ±1%
S-T segment detection Measurement rang : -0.2mv~2.0mv
Alarm: Yes,   audible and visual alarm, alarm events review
High resolution 12.1"color TFT display        
Light weight, compact and portable 
ECG, APO2, NIBP, RESP, 2-TEMP, PR          
Optional: 2-IBP, ETCO2, And thermal printer 
Built-in rechargeable lithium battery        
ECG waveforms of 7-leads display on the same screen
72-hours graphic and tabular trends of all parameters
72 alarm events of all parameters recall        
32 seconds full-disclosure waveform review 
500 NIBP measurement date can be storage and recall
Date and waveforms color be adjustable       
Arrhythmia analysis and S-T segment analysis
Suitable for adult, pediatric and neonatal patient
NIBPMethod: Oscillometry                        
Modes: Manual/Auto/Continuous
Auto measure time: Adjustable                
Measurement rang: 10-270mmHg
SPO2Measurement range: 0-100%                 
Accyracy: 70-100%, ±2% 0-69%, upspecified
Pulse rateRange: 20-254bpm                          
Accuracy: ±3bpm
RespirationMethod: RA-LL impedance                   
Range: Adult: 0-120rpm; pediatric/neonatal: 0-150rpm
Apnea alarm Yes
TemperatureRange: 0-50°C          
Apnea: 0.1°C       
Channel: Dual-Channel
 