Medical Equipment Best Infant Ventilator PA-700b

Type: Ventilator
Used for: Infant
Working Mode (Ventilation Mode): Cmv, Imv, CPAP, Manual
Breath Rate: 1 ~ 120bpm
Inspiratory Flow: 3 L/Min ~ 20 L/Min
Tidal Volume: Minimum 10 Ml ~ 300 Ml
Customization:
Diamond Member Since 2009

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
PA-700B
Oxygen Concentration of Output Gas
21% ~ 100%
Peep
0 Kpa ~ 2.0 Kpa
Kind
Orthopedics
Certification
CE, ISO13485
Group
Children
LCD Display
with LCD Display
Source
Oxygen
Anesthesia
Closed Circuit
Type of Operating Light
Double Operating Light
Transport Package
Paper Box
Specification
CE, ISO13485
Trademark
SEEUCO
Origin
Jiangsu, China
HS Code
90192000
Production Capacity
60PCS/Month

Product Description

Infant Ventilator PA-700B
Medical Equipment Best Infant Ventilator PA-700b
Specifications:
1.Working Mode (Ventilation Mode): Controlled Mechanical Ventilation (CMV),
Intermittent Mandatory Ventilation (IMV),
Continuous Positive Airway Pressure (CPAP)
Manual Ventilation (Manual) ;
2.Breath rate:1 ~ 120BPM;
3.Inspiratory to Expiratory Ratio:1:1 ~ 1:3(Special order I:E range: 10:1 ~ 1:9.9);
4.Inspiratory flow:3 L/min ~ 20 L/min;
5.Tidal volume:Minimum 10 mL ~ 300 mL;
6.Minute Volume: Max. ventilation volume greater than 5 L/min;
7.Oxygen Concentration of Output Gas: 21% ~ 100%;
8.Ventilator System Compliance :not greater than 3×10-2 mL/Pa;
9.PEEP: 0 kPa ~ 2.0 kPa;
10.Inhalation Safety Valve : Safety valve shall be opened when the airway pressure is within -300 Pa ~ -800 Pa;
11.Inspiratory Pressure:1 kPa ~ 9 kPa;
12.Inspiratory Time:0.2 s ~ 3.0 s;
13.Synchronous Trigger: Pressure Trigger: -1.0 ~ 0kPa; (Special Order)
                      Flow Trigger: 0 ~ 10L;(Special Order)
14.Maximum Safe Pressure:not greater than 10 kPa;
15.CPAP: 0 kPa ~ 2.0 kPa;
16.Monitoring Tidal Volume:Real-time monitoring within the adjustment range of tidal volume: <100 mL:±10 mL; ≥100 mL: ±15 %;
17.Monitoring Oxygen Concentration:21% ~ 100%;
18.Power Failure Alarm : audible alarm sounds immediately in case of power outage and lasts at least for 120 s;
19.Gas Source Failure Alarm : audible and visual alarm sounds within 6 s after gas source interruption occurs and lasts at least for 120 s;
20.Airway Pressure Lower Limit Alarm Range: PEEP +0.2 kPa;
21.Airway Pressure Upper Limit Alarm Range: inspiratory pressure +0.4 kPa.
 
Warranty: 1 year



 