Friendliness
Ÿ Compact design with light weight
Ÿ 3" large LCD screen allows infusion status to be viewed easily
Ÿ Embedded handle allows for easy transportation
Ÿ Straightforward IV set installation
Ÿ Intuitive programming procedure with quick guidance on screen
Safety
Ÿ High accuracy: ±5%, satisfying neonatal use
Ÿ Water-proof membrane on fingers preventing leakage into pump body
Ÿ Anti-bolus, Drug name display, History record, Last therapy parameter memory
Ÿ IP34 dust and water protection
Connectivity
Ÿ Nurse call/ RS 232/ DC input
Specifications and functions |
|
Dimension |
146 x 193 x 95mm |
Infusion set |
Applicable to GB 8368-2005 disposals; diametersΦ3.5-4.5mm, thickness 0.8-1.2mm |
Infusion mode |
Rate mode, Time mode, Body weight mode, Sequential mode |
Flow rate range |
0.1~1500ml/h |
Accumulated volume |
0.1~9999 ml |
VTBI |
0.1~999.9 ml, increment is 0.1 ml; 1000-9999ml, increment is 1ml |
Increment |
0.1~999.9 ml/h, increment is 0.1 ml/h; 1000~1500 ml/h, increment is 1 ml/h |
Accuracy |
≤ ±5% |
KVO rate |
0.1-5.0 ml/h, adjustable, increment is 0.1ml/h |
Bolus rate |
0.10-1500ml/h |
Purge rate |
800ml/h |
Occlusion |
Low 150±125 mmHg (20kPa); Medium 525±125 mmHg (70kPa); |
High 900±180 mmHg (120 kPa) |
|
|
Air bubble detection |
Single bubble detection: 50, 100, 250, 500, 800l μl |
Accumulated bubble detection: 0.1-4.0ml/h, adjustable |
|
|
Screen |
3.0'' LCD monochrome screen, 240 x 128 pixels |
Titration |
Yes, increment is 0.1ml/h |
Keypad lock |
Yes |
Pause |
Yes |
Self-test system |
Yes |
Last therapy parameter memory |
Yes |
Drug library |
200 drugs |
History record |
1500 events |
Weight |
<1.6kg (not including clamp) |
Handle |
Embedded handle |
Mounting type |
Standard: Vertical Pole |
Alarm Volume |
1-8 levels selectable |
Language |
8, Chinese, English, Spanish, French, Russian, Turkish, Portuguese, German |
Alarm |
|
|
|
VTBI done, VTBI near done, KVO finish, Bottle empty, door open, IV set not |
|
|
installed, occlusion, air in line, drop error, system error, system abnormal, |
|
|
battery low, battery empty, reminder, AC power disconnection, standby end |
Safety Requirement |
|
AC power |
100-240V (50/60Hz, 0.4-0.14A) |
DC power |
10-16V (2.25-1.5A) |
Battery type |
Lithium |
Battery operation time |
>4 hours@25ml/h |
Charging time |
≤6 hours@100% |
Classification |
CF, Class I |
IP Grade |
IP 34 |
Temperature |
5~40ºC for operating, -20~60ºC for storage |
Humidity |
15~95% for operating, 10~95% for storage |
Air pressure |
|
57~106kPa for operating, 50~106kPa for storage |
|
Interface |
|
|
Data interface |
|
Supported, RS232 |
Nurse Call |
|
Supported |
DC input |
|
Supported |